Best answer: Is code for foam type fire extinguisher?

SPECIFICATION FOR 9 LITERS MECHANICAL FOAM FIRE EXTINGUISHERS STORED PRESSURE TYPE AS PER IS 15683 WITH A RATING OF 4A ,55B. Requirement Specification Mechanical foam (AFFF) extinguisher stored pressure type Construction and rating shall confirm to IS 15683 .

Is code of foam extinguisher?

The details in regard to the maintenance of this appliance in efficient condition are given in IS 2190:1992 ‘Code of practice for selection, installation and maintenance of portable first-aid fire extinguishers ( second revision )’.

Is code for mechanical foam fire extinguisher?

Table 1 Materials for Construction of Various Parts of Fire Extinguisher

SI No. Component Material
viii) Foam making nozzle c) Plastic
ix) Gas cartridge
x) Hose Braided rubber or plastic
xi) Piercer Stainless steel

Is 2190 an Indian standard?

IS 2190: SELECTION, INSTALLATION AND MAINTENANCE OF FIRST-AID FIRE EXTINGUISHERS — CODE OF PRACTICE : Bureau of Indian Standards : Free Download, Borrow, and Streaming : Internet Archive.

What is code for fire extinguishers?

(1) A fire extinguisher, rated not less than 2A, shall be provided for each 3,000 square feet of the floor area, or fraction thereof. Where the floor area is less than 3,000 square feet at least one extinguisher shall be provided.

IMPORTANT:  Frequent question: How much do firefighters make in other countries?

What is foam extinguisher?

9 LITRES FOAM FIRE EXTINGUISHERS (Chemical Foam)

Foam is an effective smothering agent, used for liquid fires mainly. It acts by flowing over the liquid fuel oil surface and isolating the fire from the air, also prevents re-ignition due to the foam stability.

Which chemical is used in foam fire extinguisher?

Aluminium sulphate is used in ‘foam’ fire extinguishers, which contain radium bicarbonate and aluminium sulphate in separate receptacles on being mixed they form the foam of bubbklkes of CO2.

Is code for AFFF foam?

foam (AFFF) and Part 3 Fluoro-protein foam. The purpose of all the three types is same, that is, for use in Fire Extinguishing agent for Class ‘A’and ‘B’ flammable liquid (Hydrocarbons) fires. Alcohol resistant foam whichforms Part 4 of IS 4989, isnot covered inthis standard.

Is code of DCP fire extinguisher?

Portable dry powder fire extinguishers (other than those used for metal fires) are used for dealing Class A, B, C fires. … The details in regard to the maintenance are given in IS 2190 : 1992 ‘Code of practice for selection, installation and maintenance of portable first aid fire extinguishers ( third revision )’.

Is a 4308 a fire extinguisher?

Portable Dry Chemical Powder Type

Extinguishes fire by blanketing, displacement of air and decomposition of dry powder effects. These fire extinguishers contain Sodium Bi-carbonate based dry powder as per IS 4308 or Mono Ammonium Phosphate based Powder as per IS 14609.

Is a 2190 a fire extinguisher?

1 ABC Dry Chemical Powder Fire Extinguishers shall be tested as per IS: 2190:2010 5.2. 2 Test pressure shall be 35 kg/cm2 for a period of 2.5 minutes 5.2. 3 Test certificate shall be submitted and shall be valid for three further three years.

IMPORTANT:  Who can do fire safety audit?

Is 16018 a fire extinguisher?

OEM of fire extinguisher brand shall have authorisation from BIS to supply fire extinguishers as per IS 16018 [For 6.5 KG, 9 Kg and 22.5 Kg capacity] and IS 15683 [For 2 KG, and 4.5 Kg capacity], copy of valid IS authorisation shall be attached with the offer.

Is 15683 fire extinguisher manufacturers?

We are a leading Manufacturer of ABC Store Pressure Type Fire Extinguisher, QFC Brand Carbon Dioxide Type Fire Extinguisher, QFC Brand Water Co2 Fire Extinguisher as IS 15683, Automatic Modular type Fire Extinguisher, Water CO2 Type Fire Extinguisher and QFC Brand Foam Type Fire Extinguisher from Mumbai, India.

What are the 4 types of fire extinguishers?

There are four classes of fire extinguishers – A, B, C and D – and each class can put out a different type of fire.

  • Class A extinguishers will put out fires in ordinary combustibles such as wood and paper.
  • Class B extinguishers are for use on flammable liquids like grease, gasoline and oil.

What does NFPA 10 say?

NFPA 10 provides requirements to ensure that portable fire extinguishers will work as intended to provide a first line of defense against fires of limited size.

What extinguisher is Class C?

Tackling A Class C Fire

The only extinguisher which is safe to use on a Class C fire is a dry powder extinguisher. It works by cooling the flames until there is no longer enough heat to keep them burning. But using any other type of extinguisher will instead just spread the fuel and flames.